Effect of Secondary Air and Its Location on Emissions for Co-combustion of Lignite Coal and Woodchips in a Circulating Fluidized Bed Combustor
21st European Biomass Conference and Exhibition, Kopenhag, Denmark, 3 - 07 June 2013, (Full Text)
- Publication Type: Conference Paper / Full Text
- City: Kopenhag
- Country: Denmark
- Akdeniz University Affiliated: No
Abstract
In this study, combustion of biomass and coal was carried out in a circulating fluidized bed combustor. A Bursa/Orhaneli lignite was used as coal and woodchips were used as biomass in the experiments. Woodchips refer to the Rhododendron genus of woody plants in Ericaceae family which is mainly cultivated in the Black Sea region of Turkey. In this study, co-combustion of coal and woodchips mixtures containing 30% and 50% woodchips by weight was studied. The experimental setup consists of a circulating fluidized bed combustor column, a fuel feeding system, electrical heaters, and two cyclones. The combustor column has an inside diameter of 108 mm and a height of 6 m. The temperatures along the column are observed with thermocouples located at specific heights. The temperature of the column is kept at 850 oC during the combustion experiments. The pressure drops along the combustor column, cyclone, downcomer, and loopseal are continuously measured and observed in order to determine the solid mass flux within the combustor. A series of co-combustion tests was performed in order to investigate the effect of secondary air ratio and its location on the flue gas emissions. Secondary air is given to the combustor from five different locations along the combustor and at several secondary air ratios. During the combustion experiments, CO2, CO, O2, NO, and SO2, emissions in the flue gas was continuously measured and recorded by ABB-AO 2000 flue gas analyzer.
The results of the experiments showed that as the woodchips ratio in the fuel mixture increases for co-combustion, the combustion takes place more in the freeboard of the main column. Therefore, the maximum temperatures are seen in the freeboard rather than in the bed. Also the CO emissions increase as the woodchips percentage increases in the fuel. Addition of secondary air during the co-combustion experiments is found to increase the CO emissions and to decrease the NOx emissions slightly. Minimum CO emission is obtained when secondary air is given at 142 cm above the distributor plate. Among the secondary air ratios, 10% is seen to be the best for CO emission. NO emission decreases with increasing secondary air ratio except the case that secondary air is given at 51 cm above the distributor plate. NO emission also decreases by increasing the height of the location along the riser for secondary air injection to the combustor.