New method for intraoperative determination of proper screw insertion or screw malposition


Acikbas S., Tuncer M.

JOURNAL OF NEUROSURGERY, vol.93, no.1, pp.40-44, 2000 (SCI-Expanded, Scopus)

  • Publication Type: Article / Article
  • Volume: 93 Issue: 1
  • Publication Date: 2000
  • Doi Number: 10.3171/spi.2000.93.1.0040
  • Journal Name: JOURNAL OF NEUROSURGERY
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.40-44
  • Keywords: pedicle, screw fixation, screw malposition, spine injury, ADJACENT NEURAL STRUCTURES, THORACOLUMBAR FRACTURES, ANATOMIC RELATIONS, THORACIC PEDICLE, SPINE, FIXATION, ACCURACY
  • Akdeniz University Affiliated: No

Abstract

Object. Inadequate imaging techniques may lead to misjudgment of screw positioning when applying transpedicular instrumentation; this can create potential risks of major vessel and nerve damage. in this article the authors present a new method to determine screw malpositioning intraoperatively.