Using a clinical linac to determine the energy levels of Nb-92m via the photonuclear reaction


Aygun M., Cesur A., Dogru M., BOZTOSUN İ., DAPO H., Kanarya M., ...Daha Fazla

APPLIED RADIATION AND ISOTOPES, cilt.115, ss.97-99, 2016 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 115
  • Basım Tarihi: 2016
  • Doi Numarası: 10.1016/j.apradiso.2016.06.007
  • Dergi Adı: APPLIED RADIATION AND ISOTOPES
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.97-99
  • Anahtar Kelimeler: Photonuclear reaction, Energy levels, Clinical linac accelerator, ACTIVATION
  • Akdeniz Üniversitesi Adresli: Evet

Özet

The bremsstrahlung photons of 18 MeV end-point energy produced by a clinical linear accelerator were used to irradiate Nb-93, producing Nb-92m via the photonuclear reaction. The gamma-ray spectrum emitted by the excited nucleus was measured with high purity germanium detector. For analysis of the energy transitions, both gf3 and ROOT spectrum analysis programs were applied. The results were shown to be comparable with the literature values, demonstrating the ability to use a clinical liner accelerator in nuclear physics measurements. (C) 2016 Elsevier Ltd. All rights reserved.