Non-invasive detection of biliary leaks using Gd-EOB-DTPA-enhanced MR cholangiography: comparison with T2-weighted MR cholangiography


KANTARCI A., Pirimoglu B., Karabulut N., BAYRAKTUTAN Ü., Ogul H., ÖZTÜRK G., ...Daha Fazla

EUROPEAN RADIOLOGY, cilt.23, sa.10, ss.2713-2722, 2013 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 23 Sayı: 10
  • Basım Tarihi: 2013
  • Doi Numarası: 10.1007/s00330-013-2880-4
  • Dergi Adı: EUROPEAN RADIOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.2713-2722
  • Akdeniz Üniversitesi Adresli: Evet

Özet

To evaluate the added role of T1-weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance cholangiography (MRC) compared with T2-weighted MRC (T2w-MRC) in the detection of biliary leaks. Ninety-nine patients with suspected biliary complications underwent routine T2w-MRC and T1w contrast-enhanced (CE) MRC using Gd-EOB-DTPA to identify biliary leaks. Two observers reviewed the image sets separately and together. MRC findings were compared with those of surgery and percutaneous transhepatic cholangiopancreatography. The sensitivity, specificity and accuracy of the techniques in identifying biliary leaks were calculated. Accuracy of locating biliary leaks was superior with the combination of Gd-EOB-DTPA-enhanced MRC and T2w-MRC (P < 0.05).The mean sensitivities were 79 % vs 59 %, and the mean accuracy rates were 84 % vs 58 % for combined CE-MRC and T2w-MRC vs sole T2w-MRC. Nineteen out of 21 patients with biliary-cyst communication, 90.4 %, and 12/15 patients with post-traumatic biliary extravasations, 80 %, were detected by the combination of Gd-EOB-DTPA-enhanced MRC and T2w-MRC images, P < 0.05. Gd-EOB-DTPA-enhanced MRC yields information that complements T2w-MRC findings and improves the identification and localisation of the bile extravasations (84 % accuracy, 100 % specificity, P < 0.05). We recommend Gd-EOB-DTPA-enhanced MRC in addition to T2w-MRC to increase the preoperative accuracy of identifying and locating extravasations of bile. aEuro cent Magnetic resonance cholangiography (MRC) does not always detect bile leakage and cysto-biliary communications. aEuro cent Gd-EOB-DTPA-enhanced MRC helps by demonstrating extravasation of contrast material into fluid collections. aEuro cent Gd-EOB-DTPA-enhanced MRC also demonstrates the leakage site and bile duct injury type. aEuro cent Combined Gd-EOB-DTPA-enhanced and T2w-MRC can provide comprehensive information about biliary system. aEuro cent Gd-EOB-DTPA-enhanced MRC is non-invasive and does not use ionising radiation.