Evaluation of electromagnetic interference emitted from compact fluorescent lamps according to CISPR-15


KOCAKUŞAK A., ÇAKIR M., Yalcin S., ÖZEN Ş., HELHEL S.

Progress In Electromagnetics Research Symposium, cilt.2015-January, ss.1133-1136 identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Cilt numarası: 2015-January
  • Sayfa Sayıları: ss.1133-1136
  • Akdeniz Üniversitesi Adresli: Evet

Özet

In this study, Electromagnetic interference (EMI) emitted by the compact fluorescent lamps (CFL) having biggest pie in the market has been investigated according to CISPR-15. Emissions of CFLs vary depending on trademark, since some cannot provide the requirements of CISPR-15 standards such that they act as contaminants in the electric supply system. Conducted analysis considering the limits of CISPR-15 at 150-500 kHz frequency brings out that the effect of CFL produced by Company A at 181.298 kHz is 83.94 dBμV, whereas the effect of CFL produced by Company D at 173.593kHz frequency is 49,92dBμV, respectively. Obtained results are out of CISPR-15 limits of 66-56 dBμV.