Does blepharospasm effect biometric parameters and intraocular lens power calculations?


Basol I., İLHAN H. D.

International Ophthalmology, cilt.44, sa.1, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 44 Sayı: 1
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1007/s10792-024-03277-5
  • Dergi Adı: International Ophthalmology
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, BIOSIS, CAB Abstracts, EMBASE
  • Anahtar Kelimeler: Biometry, Blepharospasm, Botulinum neurotoxin-a, Intraocular lens, Topography
  • Akdeniz Üniversitesi Adresli: Evet

Özet

Purpose: To investigate the effect of botulinum toxin-A (BTX-A) treatment on corneal topography, ocular biometry and keratometry in patients with benign essential blepharospasm (BEB) and hemifacial spasm (HFS). Methods: This study comprised 66 eyes of 33 patients with BEB and 5 eyes of 5 patients with HFS who underwent BTX-A injections consecutively. Refractive error values, tear break-up time (TBUT), corneal topography [corneal power of flat axis (K1) and steep axis (K2), mean corneal power (Km), corneal astigmatism (K2–K1)] and ocular optical biometry [axial length (AL), anterior chamber depth (ACD)] were recorded before BTX-A treatment and 1 month after BTX-A treatment. The researchers calculated the expected emmetropic intraocular lens power (emm-IOL) using the SRK-T, Holladay, Hoffer-Q and Haigis formulas at each examination. Results: K1 (43.48 ± 2.02 vs. 43.57 ± 2.08, p = 0.036), Km (43.91 ± 1.99 vs. 43.99 ± 2.06, p = 0.024) and ACD (3.22 (2.77–3.76) vs. 3.41 (2.99–4.02), p < 0.001) values were found to be significantly higher. The expected emm-IOL according to the SRK-T (21.04 ± 1.6 vs. 20.93 ± 1.6, p = 0.048), Holladay (21.05 ± 1.6 vs. 20.91 ± 1.62, p = 0.037) and Hoffer-Q (21.08 ± 1.65 vs. 20.94 ± 1.68, p = 0.038) decreased significantly. The expected emm-IOL according to the Haigis formula slightly decreased, but it was not significant (p = 0.386). Additionally, TBUT was found to be significantly lower (p < 0.001) after BTX-A injection. Other parameters were not statistically significant (p > 0.05). Conclusions: Our study is the first in the literature to compare optic biometry data and intraocular lens power calculation formulas before and after BTX-A injection in eyes with BEB and HFS. BTX-A injection could play an important role in changing the keratometric and ACD values. It should be considered that IOL power calculations that might be unpredictable due to blepharospasm, so repeated measurements and especially measurements after releasing the spasm with BTX-A injections, are necessary in BEB and HFS.