Mean grain size determination in marbles by ultrasonic first backwall echo height measurements


Sarpun I., KILICKAYA M.

NDT & E INTERNATIONAL, cilt.39, sa.1, ss.82-86, 2006 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 39 Sayı: 1
  • Basım Tarihi: 2006
  • Doi Numarası: 10.1016/j.ndteint.2005.06.010
  • Dergi Adı: NDT & E INTERNATIONAL
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.82-86
  • Anahtar Kelimeler: grain size, ultrasound, ultrasonic relative attenuation, marble, ATTENUATION
  • Akdeniz Üniversitesi Adresli: Hayır

Özet

In ultrasonic grain size determination several techniques are in use. In this paper, the Ultrasonic Relative Attenuation (URA) method has been used to estimate the mean grain size of marble samples. Also, mean grain size versus first backwall echo height graphs have been plotted to see the direct relation between these two parameters. The results show less than 10% difference compared with values obtained in an optic microscope. In a comparison, mean grain size values of marbles determined by ultrasonic velocity methods are given. (c) 2005 Elsevier Ltd. All rights reserved.