Developmental Hip Dysplasia Segmentation of Ultrasound Images


Cevik K. K., Kocer H. E.

24th Signal Processing and Communication Application Conference (SIU), Zonguldak, Türkiye, 16 - 19 Mayıs 2016, ss.109-112 identifier identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Doi Numarası: 10.1109/siu.2016.7495688
  • Basıldığı Şehir: Zonguldak
  • Basıldığı Ülke: Türkiye
  • Sayfa Sayıları: ss.109-112
  • Anahtar Kelimeler: Developmental Hip Dysplasia, ultrasound, image processing, filtering
  • Akdeniz Üniversitesi Adresli: Hayır

Özet

In our study, Developmental Dysplasia of the Hip (DDH) is intended to automatically segmenting the ultrasound images for diagnosis. Initially, a filter is applied to the raw images. Seven different filters (Mean, Median, Gaussian, Wiener, Perona & Malik, Lee and Frost) are applied to the images and finally the output images are evaluated. Filtered DDH images were segmented and results are evaluated in the second part of the work. In the DDH diagnosis, the ilium and femoral regions are segmented by using Active Contour Models and Circular Hough Transform methods, respectively. When the segmentation process is analyzed, it is observed that the Wiener filters manage to increase the success rate due to their ability to remove speckle noise and ilium segmentation was performed with 94%. It is observed that Wiener filter was also success, besides when applied histogram equalization after filtering success rate is determined as 96% in the femoral region.