Laparoscopic retrieval of a displaced copper intrauterine device in a patient with three prior caesarean sections: a minimally invasive approach
35th Annual ESGE Congress, Krakow, Polonya, 4 - 07 Ekim 2026, ss.1011-1012, (Özet Bildiri)
- Yayın Türü: Bildiri / Özet Bildiri
- Basıldığı Şehir: Krakow
- Basıldığı Ülke: Polonya
- Sayfa Sayıları: ss.1011-1012
- Akdeniz Üniversitesi Adresli: Evet
Özet
ESGE35-0352 - VP066 Video in ePoster
Laparoscopic retrieval of a displaced copper intrauterine device in a patient with three prior caesarean sections: a minimally invasive approach Can Dinç1 , Yavuz Yılmaz1 , Ömer Faruk Öz1 , Selen Doğan2 , Nasuh Utku Doğan1 , İbrahim İnanç Mendilcioğlu3 1Akdeniz University, Obstetrics and Gynaecology- TR-MIGS, Antalya, Türkiye 2Akdeniz University, Gynecologic Oncology- Obstetrics and Gynaecology- TR-MIGS, Antalya, Türkiye 3Akdeniz University, Maternal-Foetal Medicine- Obstetrics and Gynaecology- TR-MIGS, Antalya, Türkiye
Background
To demonstrate the safe and effective laparoscopic retrieval of a displaced copper intrauterine device (IUD) in a high-risk patient with three prior caesarean sections, and to highlight the critical importance of post-insertion follow-up imaging in the timely detection of device migration.
Methods
A 26-year-old woman (gravida 3, para 3, all deliveries by caesarean section) was referred to our centre after presenting with absent IUD strings on speculum examination. A copper IUD had been inserted for contraceptive purposes three months prior at an external facility; no post-insertion follow-up imaging had been performed. Transvaginal ultrasound confirmed the device was absent from the uterine cavity. Plain abdominal X-ray demonstrated the IUD projected in the midline at the level of the aortic bifurcation, indicating intra-abdominal migration. Diagnostic laparoscopy was performed under general anaesthesia via a standard three-port technique. The abdominal cavity was systematically explored to localise and retrieve the device.
Results
Intraoperatively, the IUD was identified within the mesocolon of the ascending colon, embedded in the mesenteric fat without evidence of visceral perforation or significant adhesion formation. Complete laparoscopic retrieval was achieved without conversion to laparotomy or bowel injury. Intraoperative general surgery consultation was obtained following device retrieval. The consulting surgical team concurred that no colonic injury or bowel compromise was present, and a conservative postoperative management plan was jointly agreed upon. The patient was monitored accordingly throughout the postoperative period. The patient was discharged on postoperative day one in good clinical condition. No early or late postoperative complications were recorded.
Conclusions
Laparoscopy is a safe, efficient, and definitive approach for the retrieval of a displaced intraabdominal IUD, even in patients with a history of multiple caesarean sections. The discordance between the radiological projection (aortic bifurcation level on plain X-ray) and the true intraoperative location (ascending colon mesocolon) underscores the limitations of plain imaging and the indispensable role of laparoscopic exploration. Intraoperative multidisciplinary consultation with general surgery is recommended when the device is found in proximity to bowel structures, ensuring comprehensive assessment and safe postoperative follow-up. This case reinforces the necessity of routine post-insertion surveillance to enable early identification of device displacement and
prevent delayed complications. https://player.vimeo.com/video/1191525163?autoplay=1