Living donor kidney transplantation after desensitization in cross-match positive high sensitized patients.


Creative Commons License

Yilmaz V. T., Kisaoglu A., Dandin O., Demiryilmaz I., Koksoy S., Aydinli B., ...Daha Fazla

Hippokratia, cilt.24, sa.4, ss.182-190, 2020 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 24 Sayı: 4
  • Basım Tarihi: 2020
  • Dergi Adı: Hippokratia
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, EMBASE
  • Sayfa Sayıları: ss.182-190
  • Akdeniz Üniversitesi Adresli: Evet

Özet

Background: We aimed to evaluate the long-term results of the patients who had positive cross-match (XM) test results and underwent living donor renal transplantation after desensitization with different combinations of intravenous immunoglobulin (IVIG), plasmapheresis (PP), and rituximab.

Material and methods: Forty-nine patients who were positive for complement-dependent cytotoxicity (CDC), flow cytometric (FC), and Luminex-XM test were included in the study. Renal transplantation was performed in 16 patients who had XM (-) test after desensitization with different combinations of IVIG (n =15), PP (n =13), and rituximab (n =10). Anti-human leukocyte antigens (HLA) antibodies (anti-HLA Abs) were detected by the Luminex single antigen bead assay. Anti-thymocyte globulin was used for induction, and tacrolimus, mycophenolic acid, and prednisolone were used for maintenance therapy. Also, we evaluated the relationship between different donor-specific anti-HLA Abs and the parameters mentioned above.

Results: Antibody-mediated rejection (AMR) and acute T cell-mediated rejection rates were 18.8 % and 6.3 %, respectively. Graft survival rates at the first, third, and fifth years post-transplantation were 93.8 %, 85.2 %, and 85.2 %, respectively, and the patients' survival rates were found to be 100 %. Serum creatinine level and glomerular filtration rate were 1.5 ± 1.2 mg/dl and 69.9 ± 30.4 ml/min, respectively. The mean follow-up time was 39 ± 24 months.

Conclusions: Our study showed that kidney transplantation could be performed by effective desensitization in XM test positive patients. It was also shown that donor-specific anti-HLA DQ Ab and non-HLA Ab determination might be useful in diagnosing patients with positive cross-test and/or diagnosis of AMR. HIPPOKRATIA 2020, 24(4): 182-190.

Keywords: Desensitization; intravenous immunoglobulin; kidney transplantation; plasmapheresis; rituximab.